CVE Explorer
CVE-2025-63211
Stored cross-site scripting vulnerability in bridgetech VBC Server & Element Manager, firmware versions 6.5.0-9 thru 6.5.0-10, allows attackers to execute arbitrary code via the addName parameter to the /vbc/core/userSetupDoc/userSetupDoc endpoint.
Known exploited
Not asserted
Disputed
No
Stale source
No
Conflicts
1
Preserved source conflicts
No provider value was silently selected as the winner.
cwe · 2 assertions
{"cweId":"CWE-79","description":"CWE-79 Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')","lang":"en","type":"CWE"}
- cve_program_cvelist_v5cweurn:baitaphish:normalized-source-record:v2:a9f2535622f47d00cf90ab85391a1c5dade461330a71cb59a6c7a90e652b49be · sha256:6358dc6e11140072… · /containers/adp/0/problemTypes/0/descriptions/0
{"description":"n/a","lang":"en","type":"text"}
- cve_program_cvelist_v5cweurn:baitaphish:normalized-source-record:v2:a9f2535622f47d00cf90ab85391a1c5dade461330a71cb59a6c7a90e652b49be · sha256:6358dc6e11140072… · /containers/cna/problemTypes/0/descriptions/0
Affected products and versions
1 source assertion{"product":"n/a","vendor":"n/a","versions":[{"status":"affected","version":"n/a"}]}
- cve_program_cvelist_v5affectedurn:baitaphish:normalized-source-record:v2:a9f2535622f47d00cf90ab85391a1c5dade461330a71cb59a6c7a90e652b49be · sha256:6358dc6e11140072… · /containers/cna/affected/0
Provider-owned CVSS observations
1 source assertion{"metric":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"NONE","baseScore":6.1,"baseSeverity":"MEDIUM","confidentialityImpact":"LOW","integrityImpact":"LOW","privilegesRequired":"NONE","scope":"CHANGED","userInteraction":"REQUIRED","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N","version":"3.1"},"metric_type":"cvssV3_1"}
- cve_program_cvelist_v5cvssurn:baitaphish:normalized-source-record:v2:a9f2535622f47d00cf90ab85391a1c5dade461330a71cb59a6c7a90e652b49be · sha256:6358dc6e11140072… · /containers/adp/0/metrics/0/cvssV3_1
CWE assertions
2 source assertions{"cweId":"CWE-79","description":"CWE-79 Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')","lang":"en","type":"CWE"}
- cve_program_cvelist_v5cweurn:baitaphish:normalized-source-record:v2:a9f2535622f47d00cf90ab85391a1c5dade461330a71cb59a6c7a90e652b49be · sha256:6358dc6e11140072… · /containers/adp/0/problemTypes/0/descriptions/0
{"description":"n/a","lang":"en","type":"text"}
- cve_program_cvelist_v5cweurn:baitaphish:normalized-source-record:v2:a9f2535622f47d00cf90ab85391a1c5dade461330a71cb59a6c7a90e652b49be · sha256:6358dc6e11140072… · /containers/cna/problemTypes/0/descriptions/0
Source references
3 source assertions{"url":"https://bridgetech.tv/"}
- cve_program_cvelist_v5referenceurn:baitaphish:normalized-source-record:v2:a9f2535622f47d00cf90ab85391a1c5dade461330a71cb59a6c7a90e652b49be · sha256:6358dc6e11140072… · /containers/cna/references/0
{"url":"https://github.com/shiky8/my--cve-vulnerability-research/tree/main/CVE-2025-63211_bridgetech%20VBC%20Server%20and%20Element%20Manager%20Stored%20%20xss"}
- cve_program_cvelist_v5referenceurn:baitaphish:normalized-source-record:v2:a9f2535622f47d00cf90ab85391a1c5dade461330a71cb59a6c7a90e652b49be · sha256:6358dc6e11140072… · /containers/cna/references/1
{"tags":["exploit"],"url":"https://github.com/shiky8/my--cve-vulnerability-research/tree/main/CVE-2025-63211_bridgetech%20VBC%20Server%20and%20Element%20Manager%20Stored%20%20xss"}
- cve_program_cvelist_v5referenceurn:baitaphish:normalized-source-record:v2:a9f2535622f47d00cf90ab85391a1c5dade461330a71cb59a6c7a90e652b49be · sha256:6358dc6e11140072… · /containers/adp/0/references/0
Attribution and limitations
- CVE Program CVEList V5: Reproduce the MITRE copyright designation and CVE license in copies. Source →
Provider severity values are preserved separately. Baitaphish does not convert them into a risk rating, infer affected products, or treat EPSS as observed exploitation.