CVE Explorer
CVE-2025-6785
Securing externally available CAN wires can easily allow physical access to the CAN bus, allowing possible injection of specially formed CAN messages to control remote start functions of the vehicle. Testing completed on Tesla Model 3 vehicles with software version v11.1 (2023.20.9 ee6de92ddac5). This issue affects Model 3: With software versions from 2023.Xx before 2023.44.
Known exploited
Not asserted
Disputed
No
Stale source
No
Conflicts
1
Preserved source conflicts
No provider value was silently selected as the winner.
cwe · 2 assertions
{"cweId":"CWE-1263","description":"CWE-1263 Improper Physical Access Control","lang":"en","type":"CWE"}
- cve_program_cvelist_v5cweurn:baitaphish:normalized-source-record:v2:8a380e983154b722fcda4918c7aa541c44a075100a4c53121fb2bd1278b7a335 · sha256:8ade7044ff69649c… · /containers/cna/problemTypes/1/descriptions/0
{"cweId":"CWE-74","description":"CWE-74 Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')","lang":"en","type":"CWE"}
- cve_program_cvelist_v5cweurn:baitaphish:normalized-source-record:v2:8a380e983154b722fcda4918c7aa541c44a075100a4c53121fb2bd1278b7a335 · sha256:8ade7044ff69649c… · /containers/cna/problemTypes/0/descriptions/0
Affected products and versions
1 source assertion{"defaultStatus":"unaffected","product":"Model 3","vendor":"Tesla","versions":[{"lessThan":"2023.44","status":"affected","version":"2023.xx","versionType":"custom"}]}
- cve_program_cvelist_v5affectedurn:baitaphish:normalized-source-record:v2:8a380e983154b722fcda4918c7aa541c44a075100a4c53121fb2bd1278b7a335 · sha256:8ade7044ff69649c… · /containers/cna/affected/0
Provider-owned CVSS observations
1 source assertion{"metric":{"Automatable":"YES","Recovery":"AUTOMATIC","Safety":"NEGLIGIBLE","attackComplexity":"LOW","attackRequirements":"NONE","attackVector":"PHYSICAL","baseScore":4.7,"baseSeverity":"MEDIUM","privilegesRequired":"NONE","providerUrgency":"AMBER","subAvailabilityImpact":"HIGH","subConfidentialityImpact":"HIGH","subIntegrityImpact":"HIGH","userInteraction":"NONE","valueDensity":"DIFFUSE","vectorString":"CVSS:4.0/AV:P/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:N/SC:H/SI:H/SA:H/S:N/AU:Y/R:A/V:D/RE:L/U:Amber","version":"4.0","vulnAvailabilityImpact":"NONE","vulnConfidentialityImpact":"NONE","vulnIntegrity…
- cve_program_cvelist_v5cvssurn:baitaphish:normalized-source-record:v2:8a380e983154b722fcda4918c7aa541c44a075100a4c53121fb2bd1278b7a335 · sha256:8ade7044ff69649c… · /containers/cna/metrics/0/cvssV4_0
CWE assertions
2 source assertions{"cweId":"CWE-1263","description":"CWE-1263 Improper Physical Access Control","lang":"en","type":"CWE"}
- cve_program_cvelist_v5cweurn:baitaphish:normalized-source-record:v2:8a380e983154b722fcda4918c7aa541c44a075100a4c53121fb2bd1278b7a335 · sha256:8ade7044ff69649c… · /containers/cna/problemTypes/1/descriptions/0
{"cweId":"CWE-74","description":"CWE-74 Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')","lang":"en","type":"CWE"}
- cve_program_cvelist_v5cweurn:baitaphish:normalized-source-record:v2:8a380e983154b722fcda4918c7aa541c44a075100a4c53121fb2bd1278b7a335 · sha256:8ade7044ff69649c… · /containers/cna/problemTypes/0/descriptions/0
Source references
1 source assertion{"tags":["third-party-advisory"],"url":"https://asrg.io/security-advisories/cve-2025-6785/"}
- cve_program_cvelist_v5referenceurn:baitaphish:normalized-source-record:v2:8a380e983154b722fcda4918c7aa541c44a075100a4c53121fb2bd1278b7a335 · sha256:8ade7044ff69649c… · /containers/cna/references/0
Attribution and limitations
- CVE Program CVEList V5: Reproduce the MITRE copyright designation and CVE license in copies. Source →
Provider severity values are preserved separately. Baitaphish does not convert them into a risk rating, infer affected products, or treat EPSS as observed exploitation.