CVE Explorer
CVE-2025-69425
The Ruckus vRIoT IoT Controller firmware versions prior to 3.0.0.0 (GA) expose a command execution service on TCP port 2004 running with root privileges. Authentication to this service relies on a hardcoded Time-based One-Time Password (TOTP) secret and an embedded static token. An attacker who extracts these credentials from the appliance or a compromised device can generate valid authentication tokens and execute arbitrary OS commands with root privileges, resulting in complete system compromi
Known exploited
Not asserted
Disputed
No
Stale source
No
Conflicts
1
Preserved source conflicts
No provider value was silently selected as the winner.
cwe · 2 assertions
{"cweId":"CWE-798","description":"CWE-798 Use of Hard-coded Credentials","lang":"en","type":"CWE"}
- cve_program_cvelist_v5cweurn:baitaphish:normalized-source-record:v2:62c62ee9df35eb86c24e9872ec0cb19f2054662dfad01ad734040d86ef4021f7 · sha256:7fe148ac8c9a487d… · /containers/cna/problemTypes/1/descriptions/0
{"cweId":"CWE-306","description":"CWE-306 Missing Authentication for Critical Function","lang":"en","type":"CWE"}
- cve_program_cvelist_v5cweurn:baitaphish:normalized-source-record:v2:62c62ee9df35eb86c24e9872ec0cb19f2054662dfad01ad734040d86ef4021f7 · sha256:7fe148ac8c9a487d… · /containers/cna/problemTypes/0/descriptions/0
Affected products and versions
1 source assertion{"defaultStatus":"unaffected","product":"vRIoT IoT Controller","vendor":"RUCKUS Networks","versions":[{"lessThan":"3.0.0.0 (GA)","status":"affected","version":"2.3.0.0 (GA)","versionType":"custom"},{"lessThan":"3.0.0.0 (GA)","status":"affected","version":"2.3.1.0 (MR)","versionType":"custom"},{"lessThan":"3.0.0.0 (GA)","status":"affected","version":"2.4.0.0 (GA)","versionType":"custom"}]}
- cve_program_cvelist_v5affectedurn:baitaphish:normalized-source-record:v2:62c62ee9df35eb86c24e9872ec0cb19f2054662dfad01ad734040d86ef4021f7 · sha256:7fe148ac8c9a487d… · /containers/cna/affected/0
Provider-owned CVSS observations
1 source assertion{"metric":{"Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","Safety":"NOT_DEFINED","attackComplexity":"LOW","attackRequirements":"NONE","attackVector":"NETWORK","baseScore":10,"baseSeverity":"CRITICAL","exploitMaturity":"NOT_DEFINED","privilegesRequired":"NONE","providerUrgency":"NOT_DEFINED","subAvailabilityImpact":"HIGH","subConfidentialityImpact":"HIGH","subIntegrityImpact":"HIGH","userInteraction":"NONE","valueDensity":"NOT_DEFINED","vectorString":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H","version":"4.0","vulnAvailabilityImpact":"HIGH","vulnConfidentialityImpact…
- cve_program_cvelist_v5cvssurn:baitaphish:normalized-source-record:v2:62c62ee9df35eb86c24e9872ec0cb19f2054662dfad01ad734040d86ef4021f7 · sha256:7fe148ac8c9a487d… · /containers/cna/metrics/0/cvssV4_0
CWE assertions
2 source assertions{"cweId":"CWE-798","description":"CWE-798 Use of Hard-coded Credentials","lang":"en","type":"CWE"}
- cve_program_cvelist_v5cweurn:baitaphish:normalized-source-record:v2:62c62ee9df35eb86c24e9872ec0cb19f2054662dfad01ad734040d86ef4021f7 · sha256:7fe148ac8c9a487d… · /containers/cna/problemTypes/1/descriptions/0
{"cweId":"CWE-306","description":"CWE-306 Missing Authentication for Critical Function","lang":"en","type":"CWE"}
- cve_program_cvelist_v5cweurn:baitaphish:normalized-source-record:v2:62c62ee9df35eb86c24e9872ec0cb19f2054662dfad01ad734040d86ef4021f7 · sha256:7fe148ac8c9a487d… · /containers/cna/problemTypes/0/descriptions/0
Source references
2 source assertions{"tags":["vendor-advisory","patch"],"url":"https://support.ruckuswireless.com/security_bulletins/336"}
- cve_program_cvelist_v5referenceurn:baitaphish:normalized-source-record:v2:62c62ee9df35eb86c24e9872ec0cb19f2054662dfad01ad734040d86ef4021f7 · sha256:7fe148ac8c9a487d… · /containers/cna/references/0
{"tags":["third-party-advisory"],"url":"https://www.vulncheck.com/advisories/ruckus-vriot-iot-controller-hardcoded-tokens-rce"}
- cve_program_cvelist_v5referenceurn:baitaphish:normalized-source-record:v2:62c62ee9df35eb86c24e9872ec0cb19f2054662dfad01ad734040d86ef4021f7 · sha256:7fe148ac8c9a487d… · /containers/cna/references/1
Attribution and limitations
- CVE Program CVEList V5: Reproduce the MITRE copyright designation and CVE license in copies. Source →
Provider severity values are preserved separately. Baitaphish does not convert them into a risk rating, infer affected products, or treat EPSS as observed exploitation.