CVE Explorer
CVE-2026-23775
Dell PowerProtect Data Domain appliances with Data Domain Operating System (DD OS) of Feature Release versions 8.0 through 8.5, LTS2025 release version 8.3.1.0 through 8.3.1.10 contain an insertion of sensitive information into log file vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to credential exposures. Authentication attempts as the compromised user would need to be authorized by a high privileged DD user. This vulnerability
Known exploited
Not asserted
Disputed
No
Stale source
No
Conflicts
0
Affected products and versions
1 source assertion{"defaultStatus":"unaffected","product":"PowerProtect Data Domain appliances","vendor":"Dell","versions":[{"lessThan":"8.6.0.0 or later","status":"affected","version":"0","versionType":"semver"},{"lessThan":"8.3.1.20 or later","status":"affected","version":"0","versionType":"semver"}]}
- cve_program_cvelist_v5affectedurn:baitaphish:normalized-source-record:v2:1e664a466fe1a659ca0b7ab359363dd0ef9527a447e2aa0b203689df104037c1 · sha256:ea07c9a0076ef7b7… · /containers/cna/affected/0
Provider-owned CVSS observations
1 source assertion{"metric":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"HIGH","baseScore":7.6,"baseSeverity":"HIGH","confidentialityImpact":"LOW","integrityImpact":"HIGH","privilegesRequired":"LOW","scope":"UNCHANGED","userInteraction":"REQUIRED","vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:L/I:H/A:H","version":"3.1"},"metric_type":"cvssV3_1"}
- cve_program_cvelist_v5cvssurn:baitaphish:normalized-source-record:v2:1e664a466fe1a659ca0b7ab359363dd0ef9527a447e2aa0b203689df104037c1 · sha256:ea07c9a0076ef7b7… · /containers/cna/metrics/0/cvssV3_1
CWE assertions
1 source assertion{"cweId":"CWE-532","description":"CWE-532: Insertion of Sensitive Information into Log File","lang":"en","type":"CWE"}
- cve_program_cvelist_v5cweurn:baitaphish:normalized-source-record:v2:1e664a466fe1a659ca0b7ab359363dd0ef9527a447e2aa0b203689df104037c1 · sha256:ea07c9a0076ef7b7… · /containers/cna/problemTypes/0/descriptions/0
Source references
1 source assertion{"tags":["vendor-advisory"],"url":"https://www.dell.com/support/kbdoc/en-us/000450699/dsa-2026-060-security-update-for-dell-powerprotect-data-domain-multiple-vulnerabilities"}
- cve_program_cvelist_v5referenceurn:baitaphish:normalized-source-record:v2:1e664a466fe1a659ca0b7ab359363dd0ef9527a447e2aa0b203689df104037c1 · sha256:ea07c9a0076ef7b7… · /containers/cna/references/0
Attribution and limitations
- CVE Program CVEList V5: Reproduce the MITRE copyright designation and CVE license in copies. Source →
Provider severity values are preserved separately. Baitaphish does not convert them into a risk rating, infer affected products, or treat EPSS as observed exploitation.