CVE Explorer
CVE-2026-2401
CWE-532 Insertion of Sensitive Information into Log File vulnerability exists that could cause confidential information to be exposed when a Web Admin user executes a malicious file provided by an attacker.
Known exploited
Not asserted
Disputed
No
Stale source
No
Conflicts
0
Affected products and versions
1 source assertion{"defaultStatus":"unaffected","product":"PowerChute™ Serial Shutdown","vendor":"Schneider Electric","versions":[{"status":"affected","version":"Versions 1.4 and prior"}]}
- cve_program_cvelist_v5affectedurn:baitaphish:normalized-source-record:v2:779cb5d80b73cdfa3fcfb1a222909f24d4065a936b6872fb9668a94def6077bc · sha256:a6e5c73c651a8254… · /containers/cna/affected/0
Provider-owned CVSS observations
1 source assertion{"metric":{"Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","Safety":"NOT_DEFINED","attackComplexity":"LOW","attackRequirements":"NONE","attackVector":"LOCAL","baseScore":2.4,"baseSeverity":"LOW","exploitMaturity":"NOT_DEFINED","privilegesRequired":"LOW","providerUrgency":"NOT_DEFINED","subAvailabilityImpact":"NONE","subConfidentialityImpact":"NONE","subIntegrityImpact":"NONE","userInteraction":"PASSIVE","valueDensity":"NOT_DEFINED","vectorString":"CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:P/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N","version":"4.0","vulnAvailabilityImpact":"NONE","vulnConfidentialityImpact":"L…
- cve_program_cvelist_v5cvssurn:baitaphish:normalized-source-record:v2:779cb5d80b73cdfa3fcfb1a222909f24d4065a936b6872fb9668a94def6077bc · sha256:a6e5c73c651a8254… · /containers/cna/metrics/0/cvssV4_0
CWE assertions
1 source assertion{"cweId":"CWE-532","description":"CWE-532 Insertion of Sensitive Information into Log File","lang":"en","type":"CWE"}
- cve_program_cvelist_v5cweurn:baitaphish:normalized-source-record:v2:779cb5d80b73cdfa3fcfb1a222909f24d4065a936b6872fb9668a94def6077bc · sha256:a6e5c73c651a8254… · /containers/cna/problemTypes/0/descriptions/0
Source references
1 source assertion{"url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-104-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2026-104-01.pdf"}
- cve_program_cvelist_v5referenceurn:baitaphish:normalized-source-record:v2:779cb5d80b73cdfa3fcfb1a222909f24d4065a936b6872fb9668a94def6077bc · sha256:a6e5c73c651a8254… · /containers/cna/references/0
Attribution and limitations
- CVE Program CVEList V5: Reproduce the MITRE copyright designation and CVE license in copies. Source →
Provider severity values are preserved separately. Baitaphish does not convert them into a risk rating, infer affected products, or treat EPSS as observed exploitation.