Shenzhen Tenda AC7 firmware version V03.03.03.01_cn and prior contain an improper output encoding vulnerability in the web management interface. User-supplied input is reflected in HTTP responses without adequate escaping, allowing injection of arbitrary HTML or JavaScript in a victim’s browser context.
Known exploited
Not asserted
Disputed
No
Stale source
No
Conflicts
0
Affected products and versions
1 source assertion{"defaultStatus":"unaffected","product":"Tenda AC7","vendor":"Shenzhen Tenda Technology Co., Ltd.","versions":[{"lessThanOrEqual":"03.03.03.01_cn","status":"affected","version":"0","versionType":"custom"}]}
- cve_program_cvelist_v5affectedurn:baitaphish:normalized-source-record:v2:f3f476641783274f836636bd8f2a92f60675f732ac7b3c828f850bd854c3cc5c · sha256:d24e97cee5a8dfc4… · /containers/cna/affected/0
Provider-owned CVSS observations
1 source assertion{"metric":{"Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","Safety":"NOT_DEFINED","attackComplexity":"LOW","attackRequirements":"NONE","attackVector":"NETWORK","baseScore":5.1,"baseSeverity":"MEDIUM","privilegesRequired":"NONE","providerUrgency":"NOT_DEFINED","subAvailabilityImpact":"NONE","subConfidentialityImpact":"LOW","subIntegrityImpact":"LOW","userInteraction":"ACTIVE","valueDensity":"NOT_DEFINED","vectorString":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:A/VC:N/VI:N/VA:N/SC:L/SI:L/SA:N","version":"4.0","vulnAvailabilityImpact":"NONE","vulnConfidentialityImpact":"NONE","vulnIntegrityImpact":"N…
- cve_program_cvelist_v5cvssurn:baitaphish:normalized-source-record:v2:f3f476641783274f836636bd8f2a92f60675f732ac7b3c828f850bd854c3cc5c · sha256:d24e97cee5a8dfc4… · /containers/cna/metrics/0/cvssV4_0
CWE assertions
1 source assertion{"cweId":"CWE-79","description":"CWE-79 Improper Neutralization of Input During Web Page Generation (XSS or 'Cross-site Scripting')","lang":"en","type":"CWE"}
- cve_program_cvelist_v5cweurn:baitaphish:normalized-source-record:v2:f3f476641783274f836636bd8f2a92f60675f732ac7b3c828f850bd854c3cc5c · sha256:d24e97cee5a8dfc4… · /containers/cna/problemTypes/0/descriptions/0
Source references
2 source assertions{"tags":["product"],"url":"https://www.tendacn.com/product/AC7"}
- cve_program_cvelist_v5referenceurn:baitaphish:normalized-source-record:v2:f3f476641783274f836636bd8f2a92f60675f732ac7b3c828f850bd854c3cc5c · sha256:d24e97cee5a8dfc4… · /containers/cna/references/0
{"tags":["third-party-advisory"],"url":"https://www.vulncheck.com/advisories/tenda-ac7-reflected-xss-via-web-interface-output-encoding"}
- cve_program_cvelist_v5referenceurn:baitaphish:normalized-source-record:v2:f3f476641783274f836636bd8f2a92f60675f732ac7b3c828f850bd854c3cc5c · sha256:d24e97cee5a8dfc4… · /containers/cna/references/1
Attribution and limitations
- CVE Program CVEList V5: Reproduce the MITRE copyright designation and CVE license in copies. Source →
Provider severity values are preserved separately. Baitaphish does not convert them into a risk rating, infer affected products, or treat EPSS as observed exploitation.