CVE Explorer
CVE-2026-31847
Hidden functionality in the /goform/setSysTools endpoint in Nexxt Solutions Nebula 300+ firmware through version 12.01.01.37 allows remote enablement of a Telnet service. By sending a crafted POST request with parameters such as telnetManageEn=true and telnetPwd, an authenticated attacker can activate a Telnet service on port 23. This exposes a privileged diagnostic interface that is not intended for external access and can be used to interact with the underlying system.
Known exploited
Not asserted
Disputed
No
Stale source
No
Conflicts
0
Affected products and versions
1 source assertion{"defaultStatus":"unaffected","product":"Nebula 300+","vendor":"Nexxt Solutions","versions":[{"lessThanOrEqual":"Nebula300+_v12.01.01.37","status":"affected","version":"<= 12.01.01.37","versionType":"custom"}]}
- cve_program_cvelist_v5affectedurn:baitaphish:normalized-source-record:v2:d551436a1f3a0ba27eb1080a93ced6e2e59828ea6d1941eb8cd81d7c7b9e0b66 · sha256:8aabda656bbe231c… · /containers/cna/affected/0
Provider-owned CVSS observations
1 source assertion{"metric":{"Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","Safety":"NOT_DEFINED","attackComplexity":"LOW","attackRequirements":"NONE","attackVector":"ADJACENT","baseScore":8.5,"baseSeverity":"HIGH","exploitMaturity":"NOT_DEFINED","privilegesRequired":"HIGH","providerUrgency":"NOT_DEFINED","subAvailabilityImpact":"NONE","subConfidentialityImpact":"NONE","subIntegrityImpact":"NONE","userInteraction":"NONE","valueDensity":"NOT_DEFINED","vectorString":"CVSS:4.0/AV:A/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","version":"4.0","vulnAvailabilityImpact":"HIGH","vulnConfidentialityImpact":…
- cve_program_cvelist_v5cvssurn:baitaphish:normalized-source-record:v2:d551436a1f3a0ba27eb1080a93ced6e2e59828ea6d1941eb8cd81d7c7b9e0b66 · sha256:8aabda656bbe231c… · /containers/cna/metrics/0/cvssV4_0
CWE assertions
1 source assertion{"cweId":"CWE-912","description":"CWE-912 Hidden Functionality","lang":"en","type":"CWE"}
- cve_program_cvelist_v5cweurn:baitaphish:normalized-source-record:v2:d551436a1f3a0ba27eb1080a93ced6e2e59828ea6d1941eb8cd81d7c7b9e0b66 · sha256:8aabda656bbe231c… · /containers/cna/problemTypes/0/descriptions/0
Source references
2 source assertions{"name":"Firmware download","url":"https://nexxt-connectivity-frontend.s3.amazonaws.com/media/docs/Nebula300+_v12.01.01.37.zip"}
- cve_program_cvelist_v5referenceurn:baitaphish:normalized-source-record:v2:d551436a1f3a0ba27eb1080a93ced6e2e59828ea6d1941eb8cd81d7c7b9e0b66 · sha256:8aabda656bbe231c… · /containers/cna/references/1
{"name":"Official product page","url":"https://www.nexxtsolutions.com/connectivity/internal-products/ARN02304U6/"}
- cve_program_cvelist_v5referenceurn:baitaphish:normalized-source-record:v2:d551436a1f3a0ba27eb1080a93ced6e2e59828ea6d1941eb8cd81d7c7b9e0b66 · sha256:8aabda656bbe231c… · /containers/cna/references/0
Attribution and limitations
- CVE Program CVEList V5: Reproduce the MITRE copyright designation and CVE license in copies. Source →
Provider severity values are preserved separately. Baitaphish does not convert them into a risk rating, infer affected products, or treat EPSS as observed exploitation.