CVE Explorer
CVE-2026-5511
In the web management interface of Archer AX72 (SG) v1, the network diagnostic feature improperly handles invalid user input, resulting in limited exposure of diagnostic command usage information.
An authenticated attacker with administrative privileges could exploit this issue to confirm the presence of the diagnostic utility and view its valid command-line syntax and options. The exposed information is limited in scope and does not include sensitive system data.
Known exploited
Not asserted
Disputed
No
Stale source
No
Conflicts
0
Affected products and versions
1 source assertion{"defaultStatus":"unaffected","product":"Archer AX72 (SG) v1.0","vendor":"TP-Link Systems Inc.","versions":[{"lessThan":"1.4.6 Build 20260112 rel.66206","status":"affected","version":"0","versionType":"custom"}]}
- cve_program_cvelist_v5affectedurn:baitaphish:normalized-source-record:v2:5d0e7dbb8312dc4b30bd72d55581ba5ab7b66ec5d2331fa7576eb34dbddf2d77 · sha256:9f1a3b27acf46faa… · /containers/cna/affected/0
Provider-owned CVSS observations
1 source assertion{"metric":{"Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","Safety":"NOT_DEFINED","attackComplexity":"LOW","attackRequirements":"NONE","attackVector":"LOCAL","baseScore":4.6,"baseSeverity":"MEDIUM","exploitMaturity":"NOT_DEFINED","privilegesRequired":"HIGH","providerUrgency":"NOT_DEFINED","subAvailabilityImpact":"NONE","subConfidentialityImpact":"NONE","subIntegrityImpact":"NONE","userInteraction":"NONE","valueDensity":"NOT_DEFINED","vectorString":"CVSS:4.0/AV:L/AC:L/AT:N/PR:H/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N","version":"4.0","vulnAvailabilityImpact":"NONE","vulnConfidentialityImpact":"…
- cve_program_cvelist_v5cvssurn:baitaphish:normalized-source-record:v2:5d0e7dbb8312dc4b30bd72d55581ba5ab7b66ec5d2331fa7576eb34dbddf2d77 · sha256:9f1a3b27acf46faa… · /containers/cna/metrics/0/cvssV4_0
CWE assertions
1 source assertion{"cweId":"CWE-209","description":"CWE-209 Generation of error message containing sensitive information","lang":"en","type":"CWE"}
- cve_program_cvelist_v5cweurn:baitaphish:normalized-source-record:v2:5d0e7dbb8312dc4b30bd72d55581ba5ab7b66ec5d2331fa7576eb34dbddf2d77 · sha256:9f1a3b27acf46faa… · /containers/cna/problemTypes/0/descriptions/0
Source references
2 source assertions{"tags":["patch"],"url":"https://www.tp-link.com/sg/support/download/archer-ax72/#Firmware"}
- cve_program_cvelist_v5referenceurn:baitaphish:normalized-source-record:v2:5d0e7dbb8312dc4b30bd72d55581ba5ab7b66ec5d2331fa7576eb34dbddf2d77 · sha256:9f1a3b27acf46faa… · /containers/cna/references/0
{"tags":["vendor-advisory"],"url":"https://www.tp-link.com/us/support/faq/5096/"}
- cve_program_cvelist_v5referenceurn:baitaphish:normalized-source-record:v2:5d0e7dbb8312dc4b30bd72d55581ba5ab7b66ec5d2331fa7576eb34dbddf2d77 · sha256:9f1a3b27acf46faa… · /containers/cna/references/1
Attribution and limitations
- CVE Program CVEList V5: Reproduce the MITRE copyright designation and CVE license in copies. Source →
Provider severity values are preserved separately. Baitaphish does not convert them into a risk rating, infer affected products, or treat EPSS as observed exploitation.