CVE Explorer
CVE-2026-61392
There is a information disclosure vulnerability in some Hikvision cameras, allowing unauthenticated attackers to obtain partial information from the device’s memory.
Known exploited
Not asserted
Disputed
No
Stale source
No
Conflicts
1
Preserved source conflicts
No provider value was silently selected as the winner.
affected · 2 assertions
{"product":"DS-2CD Series","vendor":"Hikvision","versions":[{"status":"affected","version":"https://www.hikvision.com/en/support/download/firmware/security-firmware-download/","versionType":"link"}]}
- cve_program_cvelist_v5affectedurn:baitaphish:normalized-source-record:v2:36213611ec9d9be89885e43b891ebbb84483b48b1a761ba3ef76984e41d05455 · sha256:bcd514a4307386f7… · /containers/cna/affected/0
{"product":"DS-2DE Series","vendor":"Hikvision","versions":[{"status":"affected","version":"https://www.hikvision.com/en/support/download/firmware/security-firmware-download/","versionType":"link"}]}
- cve_program_cvelist_v5affectedurn:baitaphish:normalized-source-record:v2:36213611ec9d9be89885e43b891ebbb84483b48b1a761ba3ef76984e41d05455 · sha256:bcd514a4307386f7… · /containers/cna/affected/1
Affected products and versions
2 source assertions{"product":"DS-2CD Series","vendor":"Hikvision","versions":[{"status":"affected","version":"https://www.hikvision.com/en/support/download/firmware/security-firmware-download/","versionType":"link"}]}
- cve_program_cvelist_v5affectedurn:baitaphish:normalized-source-record:v2:36213611ec9d9be89885e43b891ebbb84483b48b1a761ba3ef76984e41d05455 · sha256:bcd514a4307386f7… · /containers/cna/affected/0
{"product":"DS-2DE Series","vendor":"Hikvision","versions":[{"status":"affected","version":"https://www.hikvision.com/en/support/download/firmware/security-firmware-download/","versionType":"link"}]}
- cve_program_cvelist_v5affectedurn:baitaphish:normalized-source-record:v2:36213611ec9d9be89885e43b891ebbb84483b48b1a761ba3ef76984e41d05455 · sha256:bcd514a4307386f7… · /containers/cna/affected/1
Provider-owned CVSS observations
1 source assertion{"metric":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"NONE","baseScore":5.3,"baseSeverity":"MEDIUM","confidentialityImpact":"LOW","integrityImpact":"NONE","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N","version":"3.1"},"metric_type":"cvssV3_1"}
- cve_program_cvelist_v5cvssurn:baitaphish:normalized-source-record:v2:36213611ec9d9be89885e43b891ebbb84483b48b1a761ba3ef76984e41d05455 · sha256:bcd514a4307386f7… · /containers/cna/metrics/0/cvssV3_1
CWE assertions
1 source assertion{"cweId":"CWE-200","description":"CWE-200 Exposure of Sensitive Information to an Unauthorized Actor","lang":"en","type":"CWE"}
- cve_program_cvelist_v5cweurn:baitaphish:normalized-source-record:v2:36213611ec9d9be89885e43b891ebbb84483b48b1a761ba3ef76984e41d05455 · sha256:bcd514a4307386f7… · /containers/adp/0/problemTypes/0/descriptions/0
Source references
1 source assertion{"url":"https://www.hikvision.com/en/support/cybersecurity/security-advisory/security-vulnerabilities-in-some-hikvision-cameras/"}
- cve_program_cvelist_v5referenceurn:baitaphish:normalized-source-record:v2:36213611ec9d9be89885e43b891ebbb84483b48b1a761ba3ef76984e41d05455 · sha256:bcd514a4307386f7… · /containers/cna/references/0
Attribution and limitations
- CVE Program CVEList V5: Reproduce the MITRE copyright designation and CVE license in copies. Source →
Provider severity values are preserved separately. Baitaphish does not convert them into a risk rating, infer affected products, or treat EPSS as observed exploitation.