CVE-2026-9396
Preserved source conflicts
No provider value was silently selected as the winner.
cvss · 4 assertions
{"metric":{"baseScore":6.3,"baseSeverity":"MEDIUM","vectorString":"CVSS:4.0/AV:N/AC:H/AT:N/PR:N/UI:N/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N/E:P","version":"4.0"},"metric_type":"cvssV4_0"}
- cve_program_cvelist_v5cvssurn:baitaphish:normalized-source-record:v2:63a83f97f2d2039e35c7d88c28040b41eb694e047fd7a1829287f76d69ed0da1 · sha256:bfd5617e70f233af… · /containers/cna/metrics/0/cvssV4_0
{"metric":{"baseScore":3.7,"baseSeverity":"LOW","vectorString":"CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:L/A:N/E:P/RL:X/RC:R","version":"3.0"},"metric_type":"cvssV3_0"}
- cve_program_cvelist_v5cvssurn:baitaphish:normalized-source-record:v2:63a83f97f2d2039e35c7d88c28040b41eb694e047fd7a1829287f76d69ed0da1 · sha256:bfd5617e70f233af… · /containers/cna/metrics/2/cvssV3_0
{"metric":{"baseScore":2.6,"vectorString":"AV:N/AC:H/Au:N/C:N/I:P/A:N/E:POC/RL:ND/RC:UR","version":"2.0"},"metric_type":"cvssV2_0"}
- cve_program_cvelist_v5cvssurn:baitaphish:normalized-source-record:v2:63a83f97f2d2039e35c7d88c28040b41eb694e047fd7a1829287f76d69ed0da1 · sha256:bfd5617e70f233af… · /containers/cna/metrics/3/cvssV2_0
{"metric":{"baseScore":3.7,"baseSeverity":"LOW","vectorString":"CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:L/A:N/E:P/RL:X/RC:R","version":"3.1"},"metric_type":"cvssV3_1"}
- cve_program_cvelist_v5cvssurn:baitaphish:normalized-source-record:v2:63a83f97f2d2039e35c7d88c28040b41eb694e047fd7a1829287f76d69ed0da1 · sha256:bfd5617e70f233af… · /containers/cna/metrics/1/cvssV3_1
Affected products and versions
1 source assertion{"cpes":["cpe:2.3:a:besen:bs20_ev_charging_station:*:*:*:*:*:*:*:*"],"modules":["Firmware Version Check"],"product":"BS20 EV Charging Station","vendor":"Besen","versions":[{"status":"affected","version":"20260426"}]}
- cve_program_cvelist_v5affectedurn:baitaphish:normalized-source-record:v2:63a83f97f2d2039e35c7d88c28040b41eb694e047fd7a1829287f76d69ed0da1 · sha256:bfd5617e70f233af… · /containers/cna/affected/0
Provider-owned CVSS observations
4 source assertions{"metric":{"baseScore":6.3,"baseSeverity":"MEDIUM","vectorString":"CVSS:4.0/AV:N/AC:H/AT:N/PR:N/UI:N/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N/E:P","version":"4.0"},"metric_type":"cvssV4_0"}
- cve_program_cvelist_v5cvssurn:baitaphish:normalized-source-record:v2:63a83f97f2d2039e35c7d88c28040b41eb694e047fd7a1829287f76d69ed0da1 · sha256:bfd5617e70f233af… · /containers/cna/metrics/0/cvssV4_0
{"metric":{"baseScore":3.7,"baseSeverity":"LOW","vectorString":"CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:L/A:N/E:P/RL:X/RC:R","version":"3.0"},"metric_type":"cvssV3_0"}
- cve_program_cvelist_v5cvssurn:baitaphish:normalized-source-record:v2:63a83f97f2d2039e35c7d88c28040b41eb694e047fd7a1829287f76d69ed0da1 · sha256:bfd5617e70f233af… · /containers/cna/metrics/2/cvssV3_0
{"metric":{"baseScore":2.6,"vectorString":"AV:N/AC:H/Au:N/C:N/I:P/A:N/E:POC/RL:ND/RC:UR","version":"2.0"},"metric_type":"cvssV2_0"}
- cve_program_cvelist_v5cvssurn:baitaphish:normalized-source-record:v2:63a83f97f2d2039e35c7d88c28040b41eb694e047fd7a1829287f76d69ed0da1 · sha256:bfd5617e70f233af… · /containers/cna/metrics/3/cvssV2_0
{"metric":{"baseScore":3.7,"baseSeverity":"LOW","vectorString":"CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:L/A:N/E:P/RL:X/RC:R","version":"3.1"},"metric_type":"cvssV3_1"}
- cve_program_cvelist_v5cvssurn:baitaphish:normalized-source-record:v2:63a83f97f2d2039e35c7d88c28040b41eb694e047fd7a1829287f76d69ed0da1 · sha256:bfd5617e70f233af… · /containers/cna/metrics/1/cvssV3_1
CWE assertions
1 source assertion{"cweId":"CWE-1021","description":"Improper Restriction of Rendered UI Layers","lang":"en","type":"CWE"}
- cve_program_cvelist_v5cweurn:baitaphish:normalized-source-record:v2:63a83f97f2d2039e35c7d88c28040b41eb694e047fd7a1829287f76d69ed0da1 · sha256:bfd5617e70f233af… · /containers/cna/problemTypes/0/descriptions/0
Source references
4 source assertions{"tags":["related"],"url":"https://github.com/carfeii/besen#finding-3-firmware-version-check-manipulation-and-ui-spoofing"}
- cve_program_cvelist_v5referenceurn:baitaphish:normalized-source-record:v2:63a83f97f2d2039e35c7d88c28040b41eb694e047fd7a1829287f76d69ed0da1 · sha256:bfd5617e70f233af… · /containers/cna/references/3
{"name":"Submit #813575 | Besen EV Charging Station BS20 EV Charger Improper Verification of Cryptographic Signature","tags":["third-party-advisory"],"url":"https://vuldb.com/submit/813575"}
- cve_program_cvelist_v5referenceurn:baitaphish:normalized-source-record:v2:63a83f97f2d2039e35c7d88c28040b41eb694e047fd7a1829287f76d69ed0da1 · sha256:bfd5617e70f233af… · /containers/cna/references/2
{"name":"VDB-365377 | Besen BS20 EV Charging Station Firmware Version Check ui layer","tags":["vdb-entry"],"url":"https://vuldb.com/vuln/365377"}
- cve_program_cvelist_v5referenceurn:baitaphish:normalized-source-record:v2:63a83f97f2d2039e35c7d88c28040b41eb694e047fd7a1829287f76d69ed0da1 · sha256:bfd5617e70f233af… · /containers/cna/references/0
{"name":"VDB-365377 | CTI Indicators (IOB, IOC)","tags":["signature","permissions-required"],"url":"https://vuldb.com/vuln/365377/cti"}
- cve_program_cvelist_v5referenceurn:baitaphish:normalized-source-record:v2:63a83f97f2d2039e35c7d88c28040b41eb694e047fd7a1829287f76d69ed0da1 · sha256:bfd5617e70f233af… · /containers/cna/references/1
Attribution and limitations
- CVE Program CVEList V5: Reproduce the MITRE copyright designation and CVE license in copies. Source →
Provider severity values are preserved separately. Baitaphish does not convert them into a risk rating, infer affected products, or treat EPSS as observed exploitation.