CVE Explorer
CVE-2026-9717
CWE-78 Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability exists that could allow unauthorized execution of commands with elevated privileges, impacting system integrity, confidentiality, and availability when a privileged authenticated user interacts with a vulnerable network-exposed service.
Known exploited
Not asserted
Disputed
No
Stale source
No
Conflicts
0
Affected products and versions
1 source assertion{"defaultStatus":"unaffected","product":"PowerLogic™ P7","vendor":"Schneider Electric","versions":[{"status":"affected","version":"Version V02.003.001.000 and prior"}]}
- cve_program_cvelist_v5affectedurn:baitaphish:normalized-source-record:v2:837dd827250865fe5ea876afbc5bc005956c5c08968999953ff76c61e7a3c68d · sha256:2ac51736d9af353f… · /containers/cna/affected/0
Provider-owned CVSS observations
1 source assertion{"metric":{"Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","Safety":"NOT_DEFINED","attackComplexity":"LOW","attackRequirements":"NONE","attackVector":"NETWORK","baseScore":8.6,"baseSeverity":"HIGH","exploitMaturity":"NOT_DEFINED","privilegesRequired":"HIGH","providerUrgency":"NOT_DEFINED","subAvailabilityImpact":"NONE","subConfidentialityImpact":"NONE","subIntegrityImpact":"NONE","userInteraction":"NONE","valueDensity":"NOT_DEFINED","vectorString":"CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","version":"4.0","vulnAvailabilityImpact":"HIGH","vulnConfidentialityImpact":"…
- cve_program_cvelist_v5cvssurn:baitaphish:normalized-source-record:v2:837dd827250865fe5ea876afbc5bc005956c5c08968999953ff76c61e7a3c68d · sha256:2ac51736d9af353f… · /containers/cna/metrics/0/cvssV4_0
CWE assertions
1 source assertion{"cweId":"CWE-78","description":"CWE-78 Improper neutralization of special elements used in an OS command ('OS command injection')","lang":"en","type":"CWE"}
- cve_program_cvelist_v5cweurn:baitaphish:normalized-source-record:v2:837dd827250865fe5ea876afbc5bc005956c5c08968999953ff76c61e7a3c68d · sha256:2ac51736d9af353f… · /containers/cna/problemTypes/0/descriptions/0
Source references
1 source assertion{"url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-160-03&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2026-160-03.pdf"}
- cve_program_cvelist_v5referenceurn:baitaphish:normalized-source-record:v2:837dd827250865fe5ea876afbc5bc005956c5c08968999953ff76c61e7a3c68d · sha256:2ac51736d9af353f… · /containers/cna/references/0